<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Einlassventil &#8211; Tribolias</title>
	<atom:link href="https://tribolias.com/tag/einlassventil/feed/" rel="self" type="application/rss+xml" />
	<link>https://tribolias.com</link>
	<description>Vanlifer, Ingenieur, Webdesigner</description>
	<lastBuildDate>Tue, 17 Nov 2026 14:52:07 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.4</generator>

<image>
	<url>https://tribolias.com/wp-content/uploads/2024/05/cropped-IMG_7123-32x32.png</url>
	<title>Einlassventil &#8211; Tribolias</title>
	<link>https://tribolias.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">249203457</site>	<item>
		<title>HPreiss LaFuente24: 4 Jahre Erfahrung, Wartung, Fehlersuche</title>
		<link>https://tribolias.com/wasser/lafuente24-erfahrung-4-jahre-abwasser-laeuft-dauerhaft/</link>
					<comments>https://tribolias.com/wasser/lafuente24-erfahrung-4-jahre-abwasser-laeuft-dauerhaft/#respond</comments>
		
		<dc:creator><![CDATA[Tribolias]]></dc:creator>
		<pubDate>Tue, 10 Nov 2026 10:03:12 +0000</pubDate>
				<category><![CDATA[Wasser]]></category>
		<category><![CDATA[Einlassventil]]></category>
		<category><![CDATA[FAQ]]></category>
		<category><![CDATA[Filter]]></category>
		<category><![CDATA[HPreiss]]></category>
		<category><![CDATA[LaFuente24]]></category>
		<category><![CDATA[Umkehrosmose]]></category>
		<category><![CDATA[Wartung]]></category>
		<guid isPermaLink="false">https://tribolias.com/?p=2959</guid>

					<description><![CDATA[<p>Seit Oktober 2022 läuft bei uns im Bus eine HPreiss LaFuente24 Direct Flow. Das sind jetzt vier Jahre mit unterschiedlich hartem Wasser und wechselnden Wasserstellen. Wir sind fast immer im europäischen Ausland unterwegs, von Portugal bis Griechenland. Deshalb mache ich alle Wartungen und Reparaturen an der Anlage selbst. In einem Wartungsprotokoll steht jeder Filterwechsel, jeder [&#8230;]</p>
<p>&lt;p&gt;The post <a rel="nofollow" href="https://tribolias.com/wasser/lafuente24-erfahrung-4-jahre-abwasser-laeuft-dauerhaft/">HPreiss LaFuente24: 4 Jahre Erfahrung, Wartung, Fehlersuche</a> first appeared on <a rel="nofollow" href="https://tribolias.com">Tribolias</a>.&lt;/p&gt;</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">Seit <strong>Oktober 2022</strong> läuft bei uns im Bus eine <strong>HPreiss LaFuente24 Direct Flow</strong>. Das sind jetzt vier Jahre mit unterschiedlich hartem Wasser und wechselnden Wasserstellen. Wir sind fast immer im europäischen Ausland unterwegs, von <strong>Portugal bis Griechenland</strong>. Deshalb mache ich alle Wartungen und Reparaturen an der Anlage <strong>selbst</strong>. In einem Wartungsprotokoll steht jeder Filterwechsel, jeder Ventiltausch und jeder ppm-Wert mit Datum.</p>



<p class="wp-block-paragraph">Dieser Beitrag ist die Auswertung aus diesem Protokoll: Was hält, was geht kaputt, was musst du als Ersatzteil dabeihaben, und was tust du, wenn das <strong>Abwasser dauerhaft läuft</strong> oder der <strong>Hahn tropft</strong>, so wie bei uns im Oktober und November 2026.</p>



<blockquote class="wp-block-quote is-layout-flow wp-block-quote-is-layout-flow">
<p class="wp-block-paragraph"><strong>Stand 15.11.2026:</strong></p>



<ul class="wp-block-list">
<li><strong>Oktober:</strong> Das Abwasser lief dauerhaft. Ursache war ein <strong>Einlassventil, das stromlos mechanisch offen stand</strong>. Das Vorgängerventil hatte denselben Fehler.</li>



<li><strong>10.11.:</strong> CF-Filter und RO-Membran wurden gewechselt. Das Osmosewasser fiel von <strong>44 auf 24 ppm</strong> (Frischwasser 230 ppm). Die Anlage füllt jetzt <strong>10 Liter in 3 Minuten</strong>, vorher dauerte es 15.</li>



<li><strong>Aktuell:</strong> Der Wasserhahn tropft weiter, weil das <strong>Ventil im Hahn undicht</strong> ist. Der neue Hahn ist bestellt. Ob damit auch der nächtliche Druckverlust verschwindet, trage ich hier nach.</li>
</ul>
</blockquote>



<h2 class="wp-block-heading">Kurzfassung (die wichtigsten Fakten)</h2>



<ul class="wp-block-list">
<li><strong>Anlage:</strong> HPreiss LaFuente24 Direct Flow, Umkehrosmose ohne Tank, 500 GPD, Pumpe ca. 60 W.</li>



<li><strong>Einsatz:</strong> Seit 04.10.2022 im Bus, Zulaufwasser aus dem Frischwassertank (zuletzt gemessen: 230 ppm).</li>



<li><strong>Reparatur:</strong> Alles mache ich selbst, weil wir fast immer im europäischen Ausland sind (Portugal bis Griechenland). Ein Ersatzteillager im Bus ist deshalb Pflicht.</li>



<li><strong>Häufigste Ausfallursache in 4 Jahren:</strong> die <strong>Magnetventile</strong> (Einlassventil und Autoflush-Ventil). Sie wurden 2024 bis 2026 insgesamt sechsmal getauscht.</li>



<li><strong>Oktober 2026:</strong> Abwasser lief dauerhaft, auch bei gezogenem Stecker. Ursache: Das Einlassventil stand stromlos mechanisch offen.</li>



<li><strong>Zweite Erkenntnis:</strong> Den Überdruckwächter (LA00820) habe ich getauscht und nachgestellt, ohne zu wissen, wie man ihn richtig einstellt. Danach kamen Alarme. Mit dem alten Schalter lief alles wieder.</li>



<li><strong>November 2026:</strong> Membran (nach gut 2 Jahren) und CF-Filter gewechselt. Osmosewasser 44 auf 24 ppm bei 230 ppm Frischwasser, 10 Liter in 3 Minuten statt in 15.</li>



<li><strong>Noch offen:</strong> Der Hahn tropft, weil das Ventil im Hahn undicht ist. Der neue Hahn ist bestellt. Das erklärt vermutlich auch, warum die Anlage immer wieder anspringt.</li>



<li><strong>Wasserweg davor:</strong> Alles Wasser, das in unseren 700-Liter-Frischwassertank läuft, geht zuerst durch 4 parallele Keramikfilter und dann durch 4 parallele Kohlefilter. Nach Tank und Pumpe folgt ein UV-Filter.</li>



<li><strong>Mein Fazit:</strong> Ich würde mir wieder eine HPreiss-Umkehrosmoseanlage kaufen.</li>
</ul>



<figure class="wp-block-image size-large"><img fetchpriority="high" decoding="async" width="609" height="1024" src="https://tribolias.com/wp-content/uploads/2026/11/IMG_5377-scaled-e1794921401107-609x1024.jpeg" alt="Blick auf zerlegte LaFuente 24 Umkehrosmoseanlage" class="wp-image-2984" srcset="https://tribolias.com/wp-content/uploads/2026/11/IMG_5377-scaled-e1794921401107-609x1024.jpeg 609w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5377-scaled-e1794921401107-179x300.jpeg 179w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5377-scaled-e1794921401107-768x1291.jpeg 768w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5377-scaled-e1794921401107-914x1536.jpeg 914w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5377-scaled-e1794921401107-1219x2048.jpeg 1219w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5377-scaled-e1794921401107-676x1136.jpeg 676w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5377-scaled-e1794921401107-600x1008.jpeg 600w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5377-scaled-e1794921401107.jpeg 1434w" sizes="(max-width: 609px) 100vw, 609px" /><figcaption class="wp-element-caption">Blick auf zerlegte LaFuente 24 Umkehrosmoseanlage</figcaption></figure>



<h2 class="wp-block-heading">Die Anlage in vier Jahren Praxis</h2>



<p class="wp-block-paragraph">Warum ich eine Direct-Flow-Anlage ohne Tank gewählt habe, steht in meinem Beitrag über <a href="https://tribolias.com/camper/filter/">Wasserfilter im Camper</a> und in <a href="https://tribolias.com/wasser/umkehrosmoseanlagen-pure-wasserpower-fuer-dein-zuhause-und-unterwegs/">Umkehrosmoseanlagen – Pure Wasserpower für dein Zuhause und unterwegs</a>. Die Grundlagen zur Technik (Membran, Abwasser, Remineralisierung) findest du außerdem auf <a href="https://tribolias.eu/" target="_blank" rel="noopener">Tribolias.eu – Reines Wasser für Haus &amp; Camper</a> und speziell auf der Seite <a href="https://tribolias.eu/umkehrosmose/" target="_blank" rel="noopener">Umkehrosmose</a>.</p>



<p class="wp-block-paragraph">Die Anlage hat drei Kartuschen:</p>



<ul class="wp-block-list">
<li><strong>CF:</strong> kombinierter Vorfilter aus PP und Aktivkohle (CTO)</li>



<li><strong>RO:</strong> Umkehrosmose-Membran, 500 GPD, 3010 (Ø 74 mm × 254 mm)</li>



<li><strong>CB:</strong> Aktivkohle-Nachfilter</li>
</ul>



<p class="wp-block-paragraph">Davor sitzen bei mir Wasseranschluss, ein Harz-Kalkfilter und ein Druckregler. Den Harz-Kalkfilter habe ich wegen des harten Wassers nachrüsten müssen. Die Kalkbelastung hat unsere Anlage schon einmal nach 11 Monaten lahmgelegt, siehe <a href="https://tribolias.com/camper/filter/">Wasserfilter im Camper</a>.</p>



<figure class="wp-block-image size-full"><img decoding="async" width="640" height="480" src="https://tribolias.com/wp-content/uploads/2024/05/IMG_5254.jpeg" alt="Umkehrosmoseanlage HPreiss LaFuente24 mit Energetisierer und vorgeschaltetem Kalkfilter im Küchenunterschrank" class="wp-image-408" srcset="https://tribolias.com/wp-content/uploads/2024/05/IMG_5254.jpeg 640w, https://tribolias.com/wp-content/uploads/2024/05/IMG_5254-600x450.jpeg 600w, https://tribolias.com/wp-content/uploads/2024/05/IMG_5254-300x225.jpeg 300w" sizes="(max-width: 640px) 100vw, 640px" /><figcaption class="wp-element-caption">Umkehrosmoseanlage HPreiss LaFuente24 mit Energetisierer und vorgeschaltetem Kalkfilter</figcaption></figure>



<h2 class="wp-block-heading">Zur Klarstellung: Der Wasserweg vor der Osmose</h2>



<p class="wp-block-paragraph">Die Osmoseanlage ist nicht die erste Filterstufe. Unser gesamtes Wasser läuft durch dieses System:</p>



<ol class="wp-block-list">
<li><strong>Befüllung:</strong> Alles Wasser, das in den <strong>700-Liter-Frischwassertank</strong> geht, läuft zuerst durch <strong>4 parallele Keramikfilter</strong> (je 0,2 µm) und danach durch <strong>4 parallele Kohlefilter</strong>.</li>



<li><strong>Tank:</strong> Im Tank liegen Silberkugeln bzw. Silbernetze.</li>



<li><strong>Pumpe und UV:</strong> Nach dem Tank und der Pumpe läuft das Wasser durch den <strong>UV-Filter</strong>, bevor es verteilt wird.</li>



<li><strong>Trinkwasser:</strong> Für das Trinkwasser folgt dahinter die LaFuente24 mit Kalkfilter (Harz), CF-, RO- und CB-Stufe.</li>
</ol>



<p class="wp-block-paragraph">Das ist wichtig für die ppm-Werte: Keramik und Kohle halten Schmutz, Algen und Chlor zurück, aber <strong>kein gelöstes Salz, keine Medikamentenrückstände und keinen gelösten Kalk.</strong> Deshalb sind die 230 ppm im Tank und der Kalkfilter vor der Osmose ein eigenes Thema. Den Aufbau mit Bildern, Standzeiten und Wartung beschreibe ich im Beitrag <a href="https://tribolias.com/camper/filter/">Wasserfilter im Camper</a>, die Erfahrung mit dem Grobfilter nach 80.000 Litern in <a href="https://tribolias.com/camper/wasser-grobfilter-und-cdl/">Wasser-Grobfilter und CDL</a>.</p>



<h2 class="wp-block-heading">Wartungsprotokoll: 4 Jahre in Zahlen</h2>



<figure class="wp-block-table"><table class="has-fixed-layout"><thead><tr><th>Datum</th><th>Ereignis</th><th>Wert</th></tr></thead><tbody><tr><td>04.10.2022</td><td>Einbau der Anlage</td><td>69 ppm</td></tr><tr><td>10.08.2023</td><td>Alle Filter und Membran getauscht, Kalkfilter neu</td><td>10 ppm</td></tr><tr><td>13.02.2024</td><td>Kalkfilter getauscht (teuer gegen billig, 35€ vs. 5€)</td><td></td></tr><tr><td>15.04.2024</td><td>CB-Nachfilter und Kalkfilter (billig) getauscht</td><td></td></tr><tr><td>01.06.2024</td><td>UV-Lampe und Silberkugeln getauscht</td><td></td></tr><tr><td>22.07.2024</td><td>Zwei Ventile (Spülen und Abwasser) getauscht, Kalkfilter (billig) getauscht</td><td></td></tr><tr><td>03.09.2024</td><td>RO-Membran und Kalkfilter (hochwertig) getauscht</td><td></td></tr><tr><td>11.11.2024</td><td></td><td>16 bis 19 ppm</td></tr><tr><td>18.11.2024</td><td>CB und CF (Vor- und Nachfilter) getauscht</td><td>21 bis 27 ppm</td></tr><tr><td>29.12.2024</td><td>Kalkfilter (ab jetzt nur noch den Teuren, der Schmeckt ab dem ersten Liter und nicht erst nach 50 Litern) getauscht</td><td></td></tr><tr><td>02.01.2025</td><td>Vorfilter gereinigt</td><td>360 auf 150 ppm</td></tr><tr><td>04.01.2025</td><td>Autoflush-Ventil (oben, LA00864) getauscht</td><td>78 ppm</td></tr><tr><td>13.03.2025</td><td>Anlage gespült</td><td>36 ppm</td></tr><tr><td>03.05.2025</td><td></td><td>60 ppm</td></tr><tr><td>10.05.2025</td><td>CB-Nachfilter getauscht, Anlage gespült, 12 l abgenommen</td><td>60 ppm</td></tr><tr><td>13.06.2025</td><td>Keramikfilter gereinigt, Aktivkohlefilter getauscht</td><td></td></tr><tr><td>16.06.2025</td><td>Silberplatten und Kalkfilter (hochwertig) getauscht</td><td>79 ppm, danach 46 ppm</td></tr><tr><td>31.07.2025</td><td>Beide Ventile getauscht, das obere (Autoflush) stark verkalkt</td><td>42 ppm</td></tr><tr><td>03.08.2025</td><td>Kalkfilter (hochwertig) getauscht</td><td></td></tr><tr><td>10.10.2025</td><td>Keramikfilter gereinigt, Grobfilter nach der Pumpe getauscht</td><td></td></tr><tr><td>29.11.2025</td><td>Keramikfilter gereinigt, CB (4000 l), CF (1 Jahr) und Harz (teuer) getauscht</td><td>64 ppm</td></tr><tr><td>27.02.2026</td><td>Nach Spülen und 8 l Wasser</td><td>42 ppm</td></tr><tr><td>28.02.2026</td><td>UV-Lampe getauscht</td><td></td></tr><tr><td>16.04.2026</td><td></td><td>65 ppm</td></tr><tr><td>26.04.2026</td><td>Keramikfilter gereinigt, CB (4000 l), Harz (teuer) und beide Ventile getauscht</td><td>35 ppm</td></tr><tr><td>08.06.2026</td><td></td><td>51 ppm</td></tr><tr><td>01.08.2026</td><td>Keramikfilter gereinigt</td><td></td></tr><tr><td>13.09.2026</td><td>CB-Filter getauscht</td><td>31 ppm, danach 38 ppm</td></tr><tr><td>07.10.2026</td><td></td><td>76 ppm</td></tr><tr><td>12.10.2026</td><td>Harz, Überdruckwächter und Autoflush-Ventil getauscht, Überdruckwächter nachgestellt, Abwasser läuft permanent</td><td>77 ppm</td></tr><tr><td>13.10.2026</td><td>10 l Osmosewasser dauern 15 Minuten, wenig Abwasser</td><td>80 auf 66 ppm</td></tr><tr><td>14.10.2026</td><td>Einlassventil getauscht (war mechanisch dauerhaft offen)</td><td>56 ppm</td></tr><tr><td>15.10.2026</td><td>Alten Überdruckwächter wieder eingebaut</td><td>49 ppm (Frischwasser 240 ppm)</td></tr><tr><td>31.10.2026</td><td>Keramikfilter gereinigt</td><td></td></tr><tr><td>01.11.2026</td><td>Alarm Start-/Stopp-Schutz (Rot, CF &amp; RO blau)</td><td></td></tr><tr><td>09.11.2026</td><td>Wasserhahn tropft permanent, Anlage spült alle 5 Minuten, stromlos alles dicht</td><td></td></tr><tr><td>10.11.2026</td><td>CF-Filter und RO-Membran gewechselt, 10 l in 3 Minuten, Hahn tropft weiter (Ventil im Hahn undicht, neuer Hahn bestellt)</td><td>44 ppm vorher, 24 ppm nachher (Frischwasser 230 ppm)</td></tr></tbody></table></figure>



<h3 class="wp-block-heading">Was die Zahlen zeigen</h3>



<ul class="wp-block-list">
<li><strong>Ventile sind das Verschleißteil Nr. 1.</strong> In 4 Jahren habe ich die beiden Magnetventile (Einlass und Autoflush) mehrfach getauscht, zuletzt im Oktober 2026. Das obere Autoflush-Ventil war im Juli 2025 stark verkalkt.</li>



<li><strong>Der Kalkfilter (Harz) ist die wichtigste Schutzmaßnahme,</strong> und er ist erstaunlich schnell erschöpft. Bei mir war ein Wechsel alle 3 bis 6 Monate nötig, je nach Wasserstelle.</li>



<li><strong>Der CB-Nachfilter hält etwa ein Jahr</strong> oder 4000 Liter, je nachdem, was zuerst eintritt. Die Keramikfilter reinige ich mehrmals im Jahr.</li>



<li><strong>Die Membran hielt gut zwei Jahre.</strong> Die erste hielt gut 13 Monate (08/2023 bis 09/2024), die zweite lief von 09/2024 bis 11/2026. Laut Schulungsunterlagen sind bei weichem Wasser bis zu 5 Jahre möglich. Bei unserem harten Wasser war nach gut zwei Jahren Schluss.</li>



<li><strong>Die ppm schwanken stark,</strong> je nach Frischwasser, Filterstand und Spülung. Ein Einzelwert sagt wenig. Wichtig ist das Verhältnis zum Zulaufwert. Als Faustregel gilt: Das Osmosewasser sollte unter etwa 10 % des Zulaufwerts liegen. Vor dem Wechsel waren es 44 zu 230 ppm, also etwa 19 %. Nach dem Wechsel sind es 24 zu 230 ppm, also etwa 10 %. Gewechselt wurden CF-Filter und Membran gleichzeitig. Den Effekt kann ich deshalb nicht sauber trennen. Die Werte und die deutlich höhere Geschwindigkeit sprechen aber klar für eine verbrauchte Membran.</li>



<li><strong>Die Leistung war der frühere Hinweis.</strong> Am 13.10. dauerten 10 Liter 15 Minuten, nach dem Wechsel am 10.11. nur noch 3 Minuten. Das ist mehr als die Datenblattangabe von etwa 1,5 Litern pro Minute. Ich gebe hier den Wert wieder, den ich gemessen habe. Wenn die Zeit für 10 Liter deutlich steigt, ist die Membran ein Kandidat.</li>
</ul>



<h2 class="wp-block-heading">Der Fehler im Oktober 2026: Abwasser läuft dauerhaft</h2>



<p class="wp-block-paragraph">Seit etwa einem Jahr verlor die Anlage alle ein bis zwei Stunden Druck und spülte kurz für ein bis zwei Sekunden. Tagsüber störte das nicht, nachts schon. Wir haben sie deshalb nachts ausgesteckt.</p>



<p class="wp-block-paragraph">Am 12.10.2026 kam dazu: <strong>Das Abwasser lief permanent.</strong> Das Fehlerbild: Die LED blinkte rot, die Anlage piepste dreimal. Ich habe Harz, Überdruckwächter und Autoflush-Ventil getauscht. Danach lief die Anlage zunächst gar nicht mehr, nach dem Nachstellen des Überdruckwächters wieder. Das Abwasser lief aber weiter.</p>



<p class="wp-block-paragraph">Der entscheidende Hinweis war dieser: <strong>Auch bei gezogenem Stecker lief Wasser ins Abwasser.</strong> Das war nicht viel, aber beständig, mehr als nur Tropfen.</p>



<p class="wp-block-paragraph">Das ist für die Fehlersuche ein wichtiger Gedanke. Ohne Strom sind die Magnetventile geschlossen und die Pumpe steht. Läuft trotzdem Wasser, kommt es mit Netzdruck durch ein Ventil, das nicht dicht hält.</p>



<h3 class="wp-block-heading">Die Fehlersuche</h3>



<ul class="wp-block-list">
<li>Zuerst vermutete ich ein defektes Autoflush-Ventil. Es war frisch getauscht, der Fehler blieb.</li>



<li>Dann den Hochdruckschalter. Die Pumpe schaltete aber immer sauber ab, also schied das aus.</li>



<li>Der Zulaufdruck war mit <strong>3 bar</strong> normal.</li>
</ul>



<p class="wp-block-paragraph">Übrig blieb das <strong>Einlassventil</strong>.</p>



<h3 class="wp-block-heading">Die Ursache: Einlassventil stromlos mechanisch offen</h3>



<p class="wp-block-paragraph">Am 14.10. habe ich das Einlassventil getauscht. Das alte <strong>stand stromlos komplett offen.</strong> Das Ventil davor hatte denselben Fehler und ließ beim Durchblasen noch etwas Luft durch. Zwei Einlassventile in Folge mit dem gleichen Defekt sind auffällig. Ich habe das alte Ventil zerlegt und mir <strong>Membran und Stößel</strong> angesehen. Ob Kalk oder Partikel im Sitz die Ursache waren, kann ich nicht sicher sagen. Bei hartem Wasser ist das aber meine naheliegende Vermutung.</p>



<figure class="wp-block-image size-large"><img decoding="async" width="768" height="1024" src="https://tribolias.com/wp-content/uploads/2026/11/IMG_5422-768x1024.jpeg" alt="Zerlegtes Einlassventil für LaFuente24" class="wp-image-2982" srcset="https://tribolias.com/wp-content/uploads/2026/11/IMG_5422-768x1024.jpeg 768w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5422-225x300.jpeg 225w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5422-1152x1536.jpeg 1152w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5422-1536x2048.jpeg 1536w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5422-676x901.jpeg 676w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5422-600x800.jpeg 600w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5422-scaled.jpeg 1920w" sizes="(max-width: 768px) 100vw, 768px" /><figcaption class="wp-element-caption">Zerlegtes Einlassventil für LaFuente24</figcaption></figure>



<h3 class="wp-block-heading">Der zweite Stolperstein: der Überdruckwächter</h3>



<p class="wp-block-paragraph">Nach dem Einlassventil-Tausch gab es Alarme:</p>



<ul class="wp-block-list">
<li><strong>Rot und CF blinken, dreimal piepsen:</strong> Alarm „Nicht genug Druck“. Die Anlage erkennt nach 1:30 Minuten keinen Eingangsdruck.</li>



<li><strong>Rot und CB blinken, kein Wasser am Hahn:</strong> passt zum Alarm „Überhöhte Pumpenbetriebszeit“.</li>



<li><strong>Ein kurzer Ausfall durch den Wassersensor:</strong> Er war nass, weil ich Wasser verschüttet hatte. Ein Leck war es nicht.</li>
</ul>



<p class="wp-block-paragraph">Weder Zulauf, Harzfilter noch Druckregler waren die Ursache: Druck und Durchfluss waren dort maximal. Am Ende lag es an meiner Einstellung. Ich wusste nicht, wie man den neuen Überdruckwächter richtig einstellt. <strong>Nach dem Wiedereinbau des alten Überdruckwächters lief am 15.10. alles wieder.</strong> Ich stelle solche Schalter nur noch mit Anleitung ein, die ich vorher beim Hersteller anfrage. Notier dir außerdem vor jedem Tausch den alten Zustand.</p>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="768" height="1024" src="https://tribolias.com/wp-content/uploads/2026/11/IMG_5382-768x1024.jpeg" alt="Überdruckwächter für LaFuente24 - Blick auf Druckeinstellschraube" class="wp-image-2983" srcset="https://tribolias.com/wp-content/uploads/2026/11/IMG_5382-768x1024.jpeg 768w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5382-225x300.jpeg 225w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5382-1152x1536.jpeg 1152w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5382-1536x2048.jpeg 1536w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5382-676x901.jpeg 676w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5382-600x800.jpeg 600w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5382-scaled.jpeg 1920w" sizes="(max-width: 768px) 100vw, 768px" /><figcaption class="wp-element-caption">Neuer Überdruckwächter</figcaption></figure>



<h2 class="wp-block-heading">November 2026: Membran, CF-Filter und ein tropfender Hahn</h2>



<p class="wp-block-paragraph">Am 31.10. habe ich die Keramikfilter gereinigt. Am 01.11. kam der Alarm <strong>„Start-/Stopp-Schutz“</strong> (Rot, CF und RO blau). Er löst aus, wenn die Pumpe zu oft an- und ausgeht. Am 09.11. tropfte der Wasserhahn permanent, und die Anlage spülte alle 5 Minuten. <strong>Stromlos war alles dicht und in Ordnung.</strong></p>



<h3 class="wp-block-heading">Membran und CF-Filter gewechselt</h3>



<p class="wp-block-paragraph">Am 10.11. habe ich CF-Filter und RO-Membran gewechselt. Die Membran lief seit 09/2024. Vorher hatte das Osmosewasser <strong>44 ppm bei 230 ppm Frischwasser</strong>, nachher <strong>24 ppm</strong>. Die Anlage füllt jetzt <strong>10 Liter in 3 Minuten</strong>.</p>



<p class="wp-block-paragraph">Alte RO Membran:</p>



<figure class="wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex">
<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="768" height="1024" data-id="3007" src="https://tribolias.com/wp-content/uploads/2026/11/IMG_5790-768x1024.jpeg" alt="Aufgesägte Membran" class="wp-image-3007" srcset="https://tribolias.com/wp-content/uploads/2026/11/IMG_5790-768x1024.jpeg 768w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5790-225x300.jpeg 225w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5790-1152x1536.jpeg 1152w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5790-1536x2048.jpeg 1536w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5790-676x901.jpeg 676w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5790-600x800.jpeg 600w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5790-scaled.jpeg 1920w" sizes="(max-width: 768px) 100vw, 768px" /></figure>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="768" height="1024" data-id="3008" src="https://tribolias.com/wp-content/uploads/2026/11/IMG_5791-768x1024.jpeg" alt="Blick auf die Membran" class="wp-image-3008" srcset="https://tribolias.com/wp-content/uploads/2026/11/IMG_5791-768x1024.jpeg 768w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5791-225x300.jpeg 225w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5791-1152x1536.jpeg 1152w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5791-1536x2048.jpeg 1536w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5791-676x901.jpeg 676w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5791-600x800.jpeg 600w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5791-scaled.jpeg 1920w" sizes="(max-width: 768px) 100vw, 768px" /></figure>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="768" height="1024" data-id="3006" src="https://tribolias.com/wp-content/uploads/2026/11/IMG_5789-768x1024.jpeg" alt="Membran von oben mit Kalkresten" class="wp-image-3006" srcset="https://tribolias.com/wp-content/uploads/2026/11/IMG_5789-768x1024.jpeg 768w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5789-225x300.jpeg 225w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5789-1152x1536.jpeg 1152w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5789-1536x2048.jpeg 1536w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5789-676x901.jpeg 676w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5789-600x800.jpeg 600w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5789-scaled.jpeg 1920w" sizes="(max-width: 768px) 100vw, 768px" /></figure>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1024" height="768" data-id="3005" src="https://tribolias.com/wp-content/uploads/2026/11/IMG_5788-1024x768.jpeg" alt="Deckel mit Kalkresten" class="wp-image-3005" srcset="https://tribolias.com/wp-content/uploads/2026/11/IMG_5788-1024x768.jpeg 1024w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5788-300x225.jpeg 300w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5788-768x576.jpeg 768w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5788-1536x1152.jpeg 1536w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5788-2048x1536.jpeg 2048w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5788-676x507.jpeg 676w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5788-600x450.jpeg 600w" sizes="(max-width: 1024px) 100vw, 1024px" /><figcaption class="wp-element-caption">Alte RO Membran mit vermeintlichen Kalkresten und schwarzen Ablagerungen</figcaption></figure>
</figure>



<p class="wp-block-paragraph">Alter CF- Filter:</p>



<figure class="wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-2 is-layout-flex wp-block-gallery-is-layout-flex">
<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="768" height="1024" data-id="3009" src="https://tribolias.com/wp-content/uploads/2026/11/IMG_5809-768x1024.jpeg" alt="Aufgesägter CF Filter" class="wp-image-3009" srcset="https://tribolias.com/wp-content/uploads/2026/11/IMG_5809-768x1024.jpeg 768w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5809-225x300.jpeg 225w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5809-1152x1536.jpeg 1152w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5809-1536x2048.jpeg 1536w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5809-676x901.jpeg 676w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5809-600x800.jpeg 600w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5809-scaled.jpeg 1920w" sizes="(max-width: 768px) 100vw, 768px" /><figcaption class="wp-element-caption">Aufgesägter CF Filter</figcaption></figure>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1024" height="768" data-id="3010" src="https://tribolias.com/wp-content/uploads/2026/11/IMG_5810-1024x768.jpeg" alt="CF Filter neben dem Gehäuase" class="wp-image-3010" srcset="https://tribolias.com/wp-content/uploads/2026/11/IMG_5810-1024x768.jpeg 1024w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5810-300x225.jpeg 300w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5810-768x576.jpeg 768w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5810-1536x1152.jpeg 1536w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5810-2048x1536.jpeg 2048w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5810-676x507.jpeg 676w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5810-600x450.jpeg 600w" sizes="(max-width: 1024px) 100vw, 1024px" /><figcaption class="wp-element-caption">Aufgesägter CF Filter</figcaption></figure>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1024" height="768" data-id="3011" src="https://tribolias.com/wp-content/uploads/2026/11/IMG_5811-1024x768.jpeg" alt="Aufgebrochener CF Filtereinsatz" class="wp-image-3011" srcset="https://tribolias.com/wp-content/uploads/2026/11/IMG_5811-1024x768.jpeg 1024w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5811-300x225.jpeg 300w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5811-768x576.jpeg 768w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5811-1536x1152.jpeg 1536w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5811-2048x1536.jpeg 2048w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5811-676x507.jpeg 676w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5811-600x450.jpeg 600w" sizes="(max-width: 1024px) 100vw, 1024px" /><figcaption class="wp-element-caption">Aufgebrochener CF Filtereinsatz</figcaption></figure>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="768" height="1024" data-id="3012" src="https://tribolias.com/wp-content/uploads/2026/11/IMG_5815-768x1024.jpeg" alt="Blick auf die Aktivkohle im CF Filter" class="wp-image-3012" srcset="https://tribolias.com/wp-content/uploads/2026/11/IMG_5815-768x1024.jpeg 768w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5815-225x300.jpeg 225w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5815-1152x1536.jpeg 1152w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5815-1536x2048.jpeg 1536w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5815-676x901.jpeg 676w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5815-600x800.jpeg 600w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5815-scaled.jpeg 1920w" sizes="(max-width: 768px) 100vw, 768px" /><figcaption class="wp-element-caption">Blick auf die Aktivkohle im CF Filter</figcaption></figure>
</figure>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="768" height="1024" src="https://tribolias.com/wp-content/uploads/2026/11/IMG_5764-768x1024.jpeg" alt="CF und RO Filter in Originalverpackung" class="wp-image-3041"/><figcaption class="wp-element-caption">CF und RO Filter in Originalverpackung</figcaption></figure>



<h3 class="wp-block-heading">Der Hahn tropft, weil das Ventil im Hahn undicht ist</h3>



<p class="wp-block-paragraph">Der Hahn tropfte auch nach dem Wechsel weiter. Meine Diagnose: <strong>Das Ventil im Hahn ist undicht.</strong> Das passt zum bisherigen Bild:</p>



<ul class="wp-block-list">
<li>Die Pumpe baut beim Zapfen Druck auf und schaltet danach ab. Ein Hahn, der nicht dicht schließt, lässt den Druck langsam sinken, und die Pumpe springt immer wieder an.</li>



<li>Stromlos ist alles dicht, denn ohne Pumpe steht kein Druck an.</li>



<li>Eine Pumpe, die zu oft hintereinander an- und ausgeht, löst den Alarm „Start-/Stopp-Schutz“ aus.</li>



<li>Der nächtliche Druckverlust, den wir seit etwa einem Jahr kennen, könnte dieselbe Ursache haben. Das ist eine Vermutung. Ich bestätige es hier, sobald der neue Hahn eingebaut ist.</li>
</ul>



<p class="wp-block-paragraph">Ich habe mich für einen <strong>neuen Hahn</strong> entschieden und bestellt. Entkalken kann bei einem verkalkten Gummi oder Ventilsitz helfen. Ein undichtes Ventil in der Armatur ist damit aber nicht sicher repariert. Vielleicht ist es auch gebrochen. Wenn ich es erst einmal zerlegt habe, gibt es vielleicht keinen Weg zurück. Mal sehen, wann der neue Hahn eintrifft. </p>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="827" height="1024" src="https://tribolias.com/wp-content/uploads/2026/11/IMG_5778-scaled-e1794926157312-827x1024.jpeg" alt="3 Wege Amatur mit Osmoseventil" class="wp-image-3045" srcset="https://tribolias.com/wp-content/uploads/2026/11/IMG_5778-scaled-e1794926157312-827x1024.jpeg 827w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5778-scaled-e1794926157312-242x300.jpeg 242w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5778-scaled-e1794926157312-768x951.jpeg 768w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5778-scaled-e1794926157312-1241x1536.jpeg 1241w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5778-scaled-e1794926157312-676x837.jpeg 676w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5778-scaled-e1794926157312-600x743.jpeg 600w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5778-scaled-e1794926157312.jpeg 1620w" sizes="(max-width: 827px) 100vw, 827px" /><figcaption class="wp-element-caption">3 Wege Amatur mit Osmoseventil</figcaption></figure>



<h2 class="wp-block-heading">Was die Anzeigen bedeuten</h2>



<p class="wp-block-paragraph">Laut der  Bedienungsanleitung gilt:</p>



<figure class="wp-block-table"><table class="has-fixed-layout"><thead><tr><th>Anzeige</th><th>Piepser</th><th>Bedeutung</th></tr></thead><tbody><tr><td>Rot + <strong>CF</strong> blau</td><td>3</td><td>Nicht genug Eingangsdruck (nach 1:30 min)</td></tr><tr><td>Rot + <strong>RO</strong> blau</td><td>Piepsen, 3 min</td><td>Wasserleck</td></tr><tr><td>Rot + <strong>CB</strong> blau</td><td>4</td><td>Pumpe hat zu lange gearbeitet (30 bis 33 min)</td></tr><tr><td>Rot + <strong>CF &amp; RO</strong> blau</td><td>5</td><td>Start-/Stopp-Schutz</td></tr><tr><td>Rot + <strong>CB &amp; RO</strong> blau</td><td>6</td><td>Frostschutz</td></tr></tbody></table></figure>



<p class="wp-block-paragraph">Alarme und Spülvorgänge sind nicht dasselbe. <strong>Rotes Blinken</strong> bedeutet eine Spülung, die sich nicht abbrechen lässt, etwa die Erstspülung oder die Spülung nach einem Filterwechsel (je 5 Minuten). <strong>Blaues Blinken</strong> ist eine Spülung, die sich abbrechen lässt. Also immer prüfen und abwarten, was passiert. Ist es ein Fehler, bleibt er. Allerdings hilft bei einem Alarm meistens: Strom trennen und wieder einstecken. Das funktioniert aber nur, wenn die Ursache behoben ist.</p>



<h2 class="wp-block-heading">Checkliste: Abwasser läuft dauerhaft oder der Hahn tropft</h2>



<p class="wp-block-paragraph">So gehe ich unterwegs vor, wenn ich weit weg von jeder Werkstatt bin:</p>



<ol class="wp-block-list">
<li><strong>Strom ziehen.</strong> Läuft das Abwasser weiter, ist die Ursache mechanisch. Tropft der Hahn nur mit Strom, steht Druck an der Armatur an.</li>



<li><strong>Wasseranschluss zu.</strong> Hört das Abwasser auf, kommt das Wasser aus dem Zulauf.</li>



<li><strong>Einlassventil prüfen:</strong> Schlauch am Ausgang des Ventils abziehen, Eimer drunter. Kommt stromlos Wasser, ist das Ventil defekt.</li>



<li><strong>Autoflush-Ventil prüfen,</strong> wenn das Einlassventil dicht ist.</li>



<li><strong>Hahn prüfen:</strong> Tropft er aus dem Auslauf, ist meist das Ventil oder die Dichtung in der Armatur undicht oder verkalkt.</li>



<li><strong>Zulaufdruck messen.</strong> Bei mir waren es 3 bar.</li>



<li><strong>Zeit für 10 Liter stoppen</strong> und mit dem Wert nach dem letzten Wechsel vergleichen. So erkennst du eine nachlassende Membran früh.</li>



<li><strong>Nach jedem Ventiltausch Geduld haben:</strong> Luft im System, automatische Spülungen und veränderte Einstellungen sind die häufigsten Stolpersteine.</li>



<li><strong>Einstellungen nicht auf eigene Faust ändern,</strong> etwa am Überdruckwächter. Frag vorher nach einer Anleitung und notiere den alten Zustand.</li>
</ol>



<h2 class="wp-block-heading">FAQ: Häufige Fragen zur LaFuente24</h2>



<p class="wp-block-paragraph"><strong>Wer repariert die Anlage bei euch?</strong> Ich selbst. Wir sind fast immer im europäischen Ausland unterwegs, von Portugal bis Griechenland, und es gibt keine Werkstatt um die Ecke. Deshalb führe ich ein Wartungsprotokoll und habe ein Ersatzteillager im Bus.</p>



<p class="wp-block-paragraph"><strong>Kann ich Ventile und Filter selbst tauschen?</strong> Filter und Ventile lassen sich mit etwas Geschick wechseln. Ich rate aber dazu, Einstellungen (zum Beispiel am Überdruckwächter) nicht ohne Anleitung zu verändern. Das hat bei mir im Oktober 2026 Alarme ausgelöst.</p>



<p class="wp-block-paragraph"><strong>Wie lange hält eine HPreiss LaFuente24?</strong> Meine läuft seit Oktober 2022 im Bus, also vier Jahre, und ist weiter im Einsatz. Verschleißteile wie Ventile, Filter und Membran habe ich dabei mehrfach getauscht.</p>



<p class="wp-block-paragraph"><strong>Warum läuft bei meiner LaFuente24 das Abwasser dauerhaft?</strong> Läuft es auch bei gezogenem Stecker, ist ein Magnetventil mechanisch undicht, bei mir das Einlassventil. Mit Strom kann auch ein dauerhaft angesteuertes Spülventil die Ursache sein. Die Schritte stehen in der Checkliste oben.</p>



<p class="wp-block-paragraph"><strong>Warum tropft bei meiner LaFuente24 der Hahn, und die Anlage springt immer wieder an?</strong> Bei uns ist das Ventil im Hahn undicht. Der Hahn schließt dann nicht dicht, der Druck sinkt langsam, und die Pumpe springt immer wieder an. Stromlos ist alles dicht. Ich ersetze den Hahn oder den Ventileinsatz.</p>



<p class="wp-block-paragraph"><strong>Wie oft muss man bei der LaFuente24 den Kalkfilter wechseln?</strong> Das hängt vom Wasser ab. Bei mir war es bei hartem Wasser alle 3 bis 6 Monate nötig. Ohne Kalkfilter hat harter Kalk unsere Anlage schon nach 11 Monaten lahmgelegt.</p>



<p class="wp-block-paragraph"><strong>Wie lange halten die Filter und die Membran?</strong> Laut Schulungsunterlagen: CF-Vorfilter 11.000 Liter oder 1 Jahr, RO-Membran 20.000 Liter oder 5 Jahre bei weichem Wasser, CB-Nachfilter 4000 Liter oder 1 Jahr. Es gilt, was zuerst eintritt. Bei hartem Wasser halten sie bei uns kürzer: Die Membran hielt gut zwei Jahre.</p>



<p class="wp-block-paragraph"><strong>Welche ppm sind normal?</strong> Das Osmosewasser sollte unter etwa 10 % des Zulaufwerts liegen. Bei uns waren es nach dem Membranwechsel 24 zu 230 ppm. Bei der Anlage zeigt die Wasserqualitätsanzeige blau bei bis zu 200 ppm, lila bei 200 bis 300 ppm und rot darüber. Mehr zur Technik steht auf <a href="https://tribolias.eu/umkehrosmose/" target="_blank" rel="noopener">Tribolias.eu</a>.</p>



<p class="wp-block-paragraph"><strong>Was bedeutet Rot und CF blinken mit drei Piepsern?</strong> Nicht genug Eingangsdruck. Prüf Wasseranschluss, Zulauf, Einlassventil und Niederdruckschalter.</p>



<p class="wp-block-paragraph"><strong>Welche Filter sitzen bei euch vor der Osmoseanlage?</strong> Alles Wasser, das in unseren 700-Liter-Frischwassertank geht, läuft durch 4 parallele Keramikfilter und dann durch 4 parallele Kohlefilter. Nach Tank und Pumpe folgt ein UV-Filter. Danach kommt für das Trinkwasser die LaFuente24, davor ein Harz-Kalkfilter. Details stehen im Beitrag <a href="https://tribolias.com/camper/filter/">Wasserfilter im Camper</a>.</p>



<p class="wp-block-paragraph"><strong>Wie viel Wasser liefert die Anlage?</strong> Laut Datenblatt etwa 1,5 Liter pro Minute (500 GPD), abhängig von Zulaufwasser und gelösten Stoffen. Bei uns dauerten 10 Liter vor dem Membranwechsel 15 Minuten, danach 3 Minuten.</p>



<p class="wp-block-paragraph"><strong>Was sollte ich als Ersatzteile dabeihaben?</strong> Das ist meine Liste für unterwegs, mit Artikelnummern: Einlassventil, Autoflush-Ventil, Überdruckwächter, Kalkfilter-Harz, CB-Filter, CF-Filter, Ersatzmembran sowie UV-Lampe und Silbernetze für den Tank. Mein Bestand am 10.11.2026: 2 CB-Filter, 3 Harzfilter, 2 Überdruckwächter und 2 Silbernetze. <strong>Auf null stehen:</strong> Einlassventil, Autoflush-Ventil, UV-Lampe, CF-Filter und Membran. Die muss ich nachbestellen &#8211; mal sehen wo wir uns mal wieder 4 Wochen aufhalten, damit die Post auch tatsächlich ankommt.</p>



<h2 class="wp-block-heading">Mehr zum Thema Wasser</h2>



<ul class="wp-block-list">
<li><a href="https://tribolias.com/wasser/">Wasser (Übersicht)</a></li>



<li><a href="https://tribolias.com/camper/filter/">Wasserfilter im Camper</a>: Mein Aufbau mit Keramik- und Aktivkohlefiltern, Silber im Tank und UV</li>



<li><a href="https://tribolias.com/wasser/umkehrosmoseanlagen-pure-wasserpower-fuer-dein-zuhause-und-unterwegs/">Umkehrosmoseanlagen – Pure Wasserpower</a></li>



<li><a href="https://tribolias.com/wasser/warum-ich-meinen-alten-wasserfilter-ausgetauscht-habe-und-diesen-hier-wirklich-empfehlen-kann/">Wasserfiltern auf WOW-Niveau</a></li>



<li><a href="https://tribolias.com/camper/wasser-grobfilter-und-cdl/">Wasser-Grobfilter und CDL</a>: Der Filter nach 80.000 Litern</li>



<li><a href="https://tribolias.com/camper/alb-wasserfilter/">Alb Wasserfilter</a>: Befüllungsfilter für unterwegs</li>



<li><a href="https://tribolias.com/gesundheit/ph-wert/">pH-Wert</a>: Osmosewasser ist leicht sauer</li>



<li><a href="https://tribolias.com/camper/ebook-wasserfilter-fuer-haus-und-camper-das-umfassende-handbuch-fuer-sauberes-trinkwasser-zu-hause-und-unterwegs/">Unser eBook: Wasserfilter für Haus und Camper</a></li>



<li><a href="https://tribolias.eu/" target="_blank" rel="noopener">Tribolias.eu – Reines Wasser für Haus &amp; Camper</a> und <a href="https://tribolias.eu/umkehrosmose/" target="_blank" rel="noopener">Umkehrosmose auf Tribolias.eu</a></li>
</ul>



<p class="wp-block-paragraph"><img decoding="async" src="https://tribolias.com/wp-content/uploads/2024/06/IMG_7070.jpeg" alt="Umkehrosmoseanlage LaFuente 24 mit Fehleranzeige"><br><em>Frühere Fehleranzeige an der LaFuente 24.</em></p>



<p class="wp-block-paragraph"><img decoding="async" src="https://tribolias.com/wp-content/uploads/2025/08/IMG_1603-768x1024.jpeg" alt="LaFuente24 Direct Flow Ventiltausch"><br><em>Ventiltausch bei der LaFuente24 (2025).</em></p>



<p class="wp-block-paragraph"><img decoding="async" src="https://tribolias.com/wp-content/uploads/2025/08/IMG_1601-768x1024.jpeg" alt="LaFuente24 Direct Flow Umkehrosmoseanlage"><br><em>Die LaFuente24 Direct Flow.</em></p>



<p class="wp-block-paragraph"><img decoding="async" src="https://tribolias.com/wp-content/uploads/2024/06/IMG_5304.jpeg" alt="Filterwechsel bei LaFuente 24 – Membran zerlegt"><br><em>Filterwechsel bei der LaFuente 24: Membran zerlegt (2024).</em></p>



<p class="wp-block-paragraph"><img decoding="async" src="https://tribolias.com/wp-content/uploads/2024/06/IMG_5258.jpeg" alt="Filterwechsel bei LaFuente 24 – Kohlefilter zerlegt"><br><em>Filterwechsel bei der LaFuente 24: Kohlefilter zerlegt (2024).</em></p>



<p class="wp-block-paragraph"><img decoding="async" src="https://tribolias.com/wp-content/uploads/2024/06/IMG_5251.jpeg" alt="Filterwechsel und Membranwechsel bei LaFuente 24"><br><em>Filter- und Membranwechsel (2024).</em></p>



<p class="wp-block-paragraph"><img decoding="async" src="https://tribolias.com/wp-content/uploads/2024/05/IMG_5712.jpeg" alt="Mini-Umkehrosmoseanlage als Vorfilter für den kompletten Camper Bus"><br><em>Eine zweite, kleine Osmoseanlage als Vorfilter für den ganzen Bus.</em></p>



<p class="wp-block-paragraph"><img decoding="async" src="https://tribolias.com/wp-content/uploads/2024/05/IMG_5255.jpeg" alt="Osmosewasser aus dem Hahn"><br><em>Osmosewasser aus dem Hahn.</em></p>



<p class="wp-block-paragraph"><img decoding="async" src="https://tribolias.com/wp-content/uploads/2024/04/IMG_3073-768x1024.jpeg" alt="Vibration im Wasserglas bei laufendem Busmotor"><br><em>Wasserglas bei laufendem Busmotor.</em></p>



<p class="wp-block-paragraph"><img decoding="async" src="https://tribolias.com/wp-content/uploads/2025/10/IMG_2164-768x1024.jpeg" alt="Wasserfilter nach 80.000 Litern"><br><em>Grobfilter nach 80.000 Litern.</em></p>



<p class="wp-block-paragraph"><img decoding="async" src="https://tribolias.com/wp-content/uploads/2025/08/IMG_1533-1024x768.jpeg" alt="WOW Wasserfilter für energetisch gutes Wasser"><br><em>WOW Wasserfilter.</em></p>



<h2 class="wp-block-heading">Wie die KI auf meine Seite kam</h2>



<p class="wp-block-paragraph">Eine Randnotiz: Ich habe den Fehler bei <strong>ChatGPT</strong> gesucht, und die KI hat dabei <strong>meine eigene Seite zitiert</strong>, nämlich <a href="https://tribolias.com/tag/filter/">tribolias.com/tag/filter</a>.</p>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="597" height="1024" src="https://tribolias.com/wp-content/uploads/2026/11/IMG_5384-597x1024.jpg" alt="Screenshot der ChatGPT-Antwort vom 12.10.2026, aufgenommen auf dem Handy. ChatGPT zeigt unsere Seite als Quelle („Tribolias“)." class="wp-image-3000" srcset="https://tribolias.com/wp-content/uploads/2026/11/IMG_5384-597x1024.jpg 597w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5384-175x300.jpg 175w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5384-676x1159.jpg 676w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5384-600x1029.jpg 600w, https://tribolias.com/wp-content/uploads/2026/11/IMG_5384.jpg 750w" sizes="(max-width: 597px) 100vw, 597px" /><figcaption class="wp-element-caption">Screenshot der ChatGPT-Antwort vom 12.10.2026, aufgenommen auf dem Handy. ChatGPT zeigt unsere Seite als Quelle („Tribolias“).</figcaption></figure>



<p class="wp-block-paragraph">Diese Frage hat zur Antwort mit dem Link auf Tribolias geführt. Es war meine Folgefrage an ChatGPT am <strong>12.10.2026</strong>, sie lautete: „Suche eine möglichst passende Reparaturanleitung für die H.Preiss LaFuente24. Fehlerbild: LED-Fehleranzeige. Version: ältere LaFuente24 naturpur. Zusatzangaben: LED blinkt rot, es piepst 3x, Abwasser läuft permanent. Suche auch nach baugleichen spanischen Modellen und technischen Serviceunterlagen.“</p>



<blockquote class="wp-block-quote is-layout-flow wp-block-quote-is-layout-flow">
<p class="wp-block-paragraph">„Die Seite zeigt ausdrücklich eine LaFuente24 Direct Flow mit Fehleranzeige sowie Bilder zum Ventiltausch, Filterwechsel und Membranwechsel. Das ist die konkreteste frei zugängliche Reparaturspur, die ich für dein Modell gefunden habe.“ ChatGPT, 12.10.2026</p>
</blockquote>



<p class="wp-block-paragraph">Das ist der Grund, warum ich diesen Beitrag so schreibe: mit Datum, Messwerten, Teilenummern und Fakten aus vier Jahren Betrieb statt mit Meinungen. Wer eine konkrete Frage zur LaFuente24 hat, soll hier eine belastbare Antwort finden, egal ob er sie selbst liest oder eine KI sie für ihn zitiert. Eine Quelle ersetzt aber nicht das Nachmessen: Bei Werten, Einstellungen und Wasser, das du trinkst, prüf nach. Mehr zum Thema auf unserer Seite <a href="https://tribolias.com/category/ki-suchwissen/">KI-Suchwissen</a>.</p>



<h2 class="wp-block-heading">Mein Fazit nach 4 Jahren</h2>



<p class="wp-block-paragraph">Die Fehler waren am Ende banal und trotzdem schwer zu finden: ein <strong>Einlassventil, das stromlos offen stand</strong>, ein <strong>Überdruckwächter, den ich ohne Anleitung nachgestellt hatte</strong>, eine <strong>Membran nach gut zwei Jahren</strong> und ein <strong>undichtes Ventil im Hahn</strong>. Die Anlage selbst war nie das Problem. Wer unterwegs alles selbst reparieren muss, braucht drei Dinge: ein Wartungsprotokoll, ein Ersatzteillager und die Gewohnheit, vor jedem Tausch erst zu messen. Dafür bekommt man Osmosewasser direkt aus dem Hahn, ohne Tank und ohne Kisten schleppen.</p>



<p class="wp-block-paragraph"><strong>Ich würde mir wieder eine HPreiss-Umkehrosmoseanlage kaufen.</strong> Wer eine neue Anlage sucht: Ich empfehle die <strong>WOW-Umkehrosmoseanlage</strong> von <a href="https://www.hpreiss-webshop.de" target="_blank" rel="noopener">HPreiss</a> (<a href="https://water-of-winners.com" target="_blank" rel="noopener">Produktlink</a>). Mit dem Gutscheincode <strong>W4210#</strong> bekommst du sogar noch eine Isolierkanne dazu.</p>



<p class="wp-block-paragraph"><em>Werbung: Dieser Absatz enthält Werbelinks und einen Gutscheincode.</em></p>
<p>&lt;p&gt;The post <a rel="nofollow" href="https://tribolias.com/wasser/lafuente24-erfahrung-4-jahre-abwasser-laeuft-dauerhaft/">HPreiss LaFuente24: 4 Jahre Erfahrung, Wartung, Fehlersuche</a> first appeared on <a rel="nofollow" href="https://tribolias.com">Tribolias</a>.&lt;/p&gt;</p>